{"title":"Multimeters \u0026 Clamp Meters","description":"\u003cp id=\"choose-the-instrument\"\u003eUse the UNI-T UT139C with test leads to check voltage, resistance and continuity. The UNI-T UT210E measures AC or DC current around one accessible conductor while the circuit stays connected.\u003c\/p\u003e\n\n\u003ch2 id=\"steady-dc-question\"\u003eCan the UNI-T UT139C or UT210E distinguish steady DC currents of 40 mA and 50 mA on an isolated low-voltage board, and what changes if I cannot open the circuit?\u003c\/h2\u003e\n\u003cp id=\"steady-dc-answer\"\u003eOn an isolated low-voltage board, the \u003cstrong\u003eUT139C in series\u003c\/strong\u003e can distinguish steady 40 mA from 50 mA on its published accuracy specification for the 60.00 mA DC range if you can switch off to insert it and restart the board in the same state at the required voltage. If the circuit must stay closed, the \u003cstrong\u003eUT210E\u003c\/strong\u003e can take a reading around one accessible insulated conductor. On its 2.000 A DC range the error bands overlap, so the clamp alone cannot reliably distinguish 40 mA from 50 mA.\u003c\/p\u003e\n\n\u003cp id=\"reading-the-spec\"\u003eRange tells you whether the reading fits. Resolution is the smallest display step. To work out the error allowance, add the percentage of the displayed reading to the specified number of display steps. These examples use 23 ± 5 °C and relative humidity below 75%.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli id=\"ut139c-error\"\u003e\u003cstrong\u003eUT139C, 60.00 mA DC range.\u003c\/strong\u003e The display step is 0.01 mA and accuracy is ±(0.7% of the reading + 2 digits). At a displayed 40.00 mA the allowance is ±0.30 mA (39.70–40.30 mA). At 50.00 mA it is ±0.37 mA (49.63–50.37 mA). The intervals are separate. \u003ca href=\"https:\/\/meters.uni-trend.com\/download\/ut139a-b-c-user-manual\/\"\u003eUNI-T UT139A\/B\/C manual, printed page 20, DC current table\u003c\/a\u003e.\u003c\/li\u003e\n  \u003cli id=\"ut210e-error\"\u003e\u003cstrong\u003eUT210E, 2.000 A DC clamp range.\u003c\/strong\u003e The display step is 1 mA and accuracy is ±(2% of the reading + 8 digits). At a displayed 40 mA the allowance is ±8.8 mA (31.2–48.8 mA). At 50 mA it is ±9.0 mA (41.0–59.0 mA). An actual current between 41.0 and 48.8 mA is consistent with either display. \u003ca href=\"https:\/\/meters.uni-trend.com\/download\/ut210e-user-manual\/\"\u003eUNI-T UT210E manual, section IX.6, DCA measurement\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 id=\"series-connection\"\u003eWhat should I check before opening the circuit?\u003c\/h2\u003e\n\u003cp id=\"series-method\"\u003eCheck that the steady current and any start-up peak fit the input and range you will use. Switch off the board before connecting the \u003ca href=\"\/en-uk\/products\/voltcap\"\u003eUT139C multimeter\u003c\/a\u003e in series with the load, using the mA and COM sockets. A current input placed across a supply can short it. Follow the input and time limits in the manual. The CE version specifies an FF 0.6 A H 600 V fuse for its µA\/mA input.\u003c\/p\u003e\n\u003cp id=\"burden-voltage\"\u003eA meter in series takes a small voltage drop, called burden voltage. Check that the board still receives its required voltage and returns to its original operating state. A board that resets or draws a different current after the meter is inserted gives you a reading for that changed state.\u003c\/p\u003e\n\n\u003ch2 id=\"uninterrupted-current\"\u003eWhat if I cannot open the circuit?\u003c\/h2\u003e\n\u003cp id=\"single-conductor\"\u003eWith the \u003ca href=\"\/en-uk\/products\/minidigitalc\"\u003eUT210E AC\/DC clamp meter\u003c\/a\u003e, unplug the test leads, select DC current and zero the empty, closed jaws in the orientation you will use. Centre one accessible insulated supply or return conductor in the jaws and close them fully. Recheck the empty-jaw zero afterwards. Drift matters at this scale.\u003c\/p\u003e\n\u003cp id=\"ut210e-figures\"\u003eUNI-T shows how to centre one conductor and keep the meter facing the same way during DC zeroing and measurement in \u003ca href=\"https:\/\/meters.uni-trend.com\/download\/ut210e-user-manual\/\"\u003efigures 5 and 6 of the UT210E manual\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp id=\"paired-conductors\"\u003eIf the jaws enclose both supply and return, their magnetic fields largely cancel. If you can reach only an intact two-core cable and the board must stay powered, leave the cable intact. Check whether the board provides a documented current-monitoring point with enough accuracy to distinguish 40 mA from 50 mA.\u003c\/p\u003e\n\n\u003ch2 id=\"other-checks\"\u003eWhat if I need voltage, resistance or continuity?\u003c\/h2\u003e\n\u003cp id=\"lead-checks\"\u003eTo check supply voltage on the isolated low-voltage board, use the voltage and COM sockets and place the probes across the two points of interest. For resistance or continuity, disconnect the supply and discharge any capacitors first. Both models offer these checks with test leads.\u003c\/p\u003e\n\u003cp id=\"further-reading\"\u003eA brief start-up pulse calls for a separate check of capture speed and peak range. For the worked steady-current comparison and guidance on how the meter can affect the board, see the \u003ca href=\"\/en-uk\/blogs\/news\/small-dc-current-multimeter-or-clamp-meter-ut139c-ut210e\"\u003eUK guide to measuring small DC currents\u003c\/a\u003e.\u003c\/p\u003e\n","products":[{"product_id":"voltcap","title":"UNI-T UT139C True RMS Digital Multimeter","description":"\u003ch2\u003eChoose the multimeter route for your bench checks\u003c\/h2\u003e\u003cp\u003eThe UNI-T UT139C is a handheld digital multimeter for lead-based voltage, resistance, continuity and related electrical measurements. Its 6000-count display, automatic\/manual ranging and True RMS AC measurement give you a defined set of functions to compare with your task.\u003c\/p\u003e\u003ch3\u003eWhat to compare\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExact model:\u003c\/strong\u003e UT139C, within the UNI-T UT139 family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 6000 counts. Counts describe resolution; use the applicable range accuracy for your reading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRanging:\u003c\/strong\u003e automatic and manual range selection in the manufacturer model specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC measurement:\u003c\/strong\u003e True RMS, with the UT139C manufacturer bandwidth specified as 45 Hz–1 kHz. Check amplitude, waveform and range limits in the instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTask:\u003c\/strong\u003e compare the voltage, resistance, continuity, capacitance and temperature functions with the actual measurement you need.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eMultimeter or clamp meter?\u003c\/h3\u003e\u003cp\u003eStart here when your next check uses test leads. If you need current measured with a clamp, compare the UT210E in our \u003ca href=\"\/en-uk\/collections\/multimeters-clamp-meters\"\u003emultimeter and clamp-meter range\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eUse the free \u003ca href=\"https:\/\/meterandprobe.co.uk\/bench-measurement\/counts-vs-accuracy\/\"\u003eMeter \u0026amp; Probe accuracy guide and error-limit calculator\u003c\/a\u003e to understand why more display digits do not by themselves establish a better result.\u003c\/p\u003e\u003ch3\u003eBefore you order\u003c\/h3\u003e\u003cp\u003eThe information above describes the named manufacturer model. Confirm the exact supplied leads, accessories and battery contents with Payverza before ordering. Use the model instructions for the intended function, range and environment; this listing does not independently certify a safety or installation-testing claim.\u003c\/p\u003e\u003cp\u003eModel reference: \u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut139-series\/\" target=\"_blank\" rel=\"noopener\"\u003eUNI-T UT139 series manufacturer specifications\u003c\/a\u003e, checked 17 November 2026. Product photos show the current retailer listing; no independent Meter \u0026amp; Probe hardware test is claimed.\u003c\/p\u003e","brand":"voltcap","offers":[{"title":"Default Title","offer_id":43862548316226,"sku":"B08FCD7R9P","price":110.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0112\/9873\/4146\/files\/71FOsMCiCGS._SL1500.jpg?v=1794732626"},{"product_id":"minidigitalc","title":"UNI-T UT210E Mini AC\/DC Clamp Meter","description":"\u003ch2\u003eChoose a compact current-clamp route\u003c\/h2\u003e\u003cp\u003eThe UNI-T UT210E is a mini clamp meter for AC and DC current tasks. Compare its jaw size and current ranges with the conductor access and signal you need to measure, then check the exact range accuracy in the manufacturer instructions.\u003c\/p\u003e\u003ch3\u003eKey model specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExact model:\u003c\/strong\u003e UT210E, within the UNI-T UT210 mini-clamp family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamp current:\u003c\/strong\u003e AC and DC ranges up to 100 A in the manufacturer model table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJaw opening:\u003c\/strong\u003e 17 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 2000 counts, with automatic ranging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther functions:\u003c\/strong\u003e voltage, resistance, continuity, diode and capacitance functions are listed for the model; use the appropriate leads and function instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCheck small-current requirements first\u003c\/h3\u003e\u003cp\u003eA small display step does not guarantee equally small measurement error. For battery-drain or very small current tasks, compare zero drift, range errors and conditions before deciding this clamp is appropriate.\u003c\/p\u003e\u003cp\u003eRead the free \u003ca href=\"https:\/\/meterandprobe.co.uk\/dc-current-batteries\/low-current-clamp-limitations\/\"\u003eMeter \u0026amp; Probe low-current clamp guide\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eFor lead-based bench checks, compare the UT139C in the \u003ca href=\"\/en-uk\/collections\/multimeters-clamp-meters\"\u003emultimeter and clamp-meter range\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eBefore you order\u003c\/h3\u003e\u003cp\u003eThe model specification does not establish the seller’s supplied accessory set. Confirm leads, accessories and batteries with Payverza before ordering. Follow the exact model instructions for zeroing, the selected range and conductor access. This page does not independently verify a certification or installation-testing claim.\u003c\/p\u003e\u003cp\u003eModel reference: \u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut210-series\/\" target=\"_blank\" rel=\"noopener\"\u003eUNI-T UT210 series manufacturer specifications\u003c\/a\u003e, checked 17 November 2026. Current retailer images and prices are separate from independent instrument testing.\u003c\/p\u003e","brand":"minidigitalc","offers":[{"title":"Default Title","offer_id":43902710743106,"sku":"B0BX5M4928","price":73.87,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0112\/9873\/4146\/files\/product_main_source_2301d10f-1dba-44de-8a30-64df265456b5.webp?v=1788772709"}],"url":"https:\/\/checkout.payverza.com\/en-uk\/collections\/multimeters-clamp-meters.oembed","provider":"Payverza","version":"1.0","type":"link"}