74HC393 Counter Bits Change at Different Times: Fault or Ripple Behaviour?
DigitalOsc editorial team · Updated 21 November 2026
A ripple counter does not promise that every output bit switches at the same instant. Decide whether your circuit needs a stable count or a glitch-free decoded transition before interpreting the trace.
Identify the architecture and selected outputs
TI documents the SN74HC393 as a dual binary ripple counter. Check the exact clock edge, reset behaviour and output order for your package. It is different from a synchronous counter whose output timing has another specification. A visible count sequence can be correct while a combinational circuit observing several bits sees short intermediate states during a transition.
Start with a slow known count
Use compatible safe logic levels, a known reference and a repeatable clock source. Record reset and the selected counter section. Compare the settled output states over several input events before zooming into edges. A wrong output mapping or a held reset should be resolved before deciding that a propagation effect explains everything. Do not connect another source to a clock that is already driven.
Capture one pair at a time with limits
Two inputs can compare clock with one output or compare two outputs. State which pair you actually observed; that record does not simultaneously prove every bit. Use the exact data sheet to interpret edge relationships and required timing. The absence of a visible narrow transition on a basic handheld is not proof of zero skew, and a measured screen offset is not automatically an accurate nanosecond delay.
Choose hardware for the real downstream need
If the application only reads a settled count at a valid time, a brief intermediate state may not matter. If a decoded pulse must be glitch-free, analyse the complete timing and architecture rather than adding arbitrary capacitors to hide the display. The 2C53P supplies two analogue inputs, while the OT3 supplies one; neither turns a ripple counter into a synchronous one. Retain clock, reset, load and capture settings with the evidence.
Choose a handheld for this question
Two simultaneous inputs help with the relationship described here; the FNIRSI 2C53P advertises two channels, 50 MHz and up to 250 MSa/s. Check the actual acquisition mode, capture length and probes. A single-channel OT3 cannot capture two nodes in one event.
- Check the exact 2C53P listing
- Compare the current FNIRSI and BSIDE range
- Compare 2C53P versus OT3 for your bench
DigitalOsc links to Payverza as the retailer. Confirm the exact probes, accessories, current price and delivery before purchase. This is a proposed low-voltage workflow, not an independent hardware test; a battery-powered case does not establish isolated inputs.
Sources and scope
- COUNTER manufacturer or technical documentation (source snapshot 2026-11-21)
- PICO manufacturer or technical documentation (source snapshot 2026-11-21)
Examples are illustrative, not measured results. Follow the exact device and probe documentation for pinout, voltage, reference and timing limits. Recheck specifications for the version you actually own.